  • OTDR to check the junction box

    OTDR to check the junction box

    To perform an OTDR test correctly, you must: 1. Set core parameters (Wavelength, Distance, Pulse Width); 4. Run the test (Real-time or Average); 5. If it's a long outside plant cable with intermediate splices, you will probably want to verify the individual splices with an OTDR test also, since that's the only way to make sure that each splice is good. As opposed to the simple light source and power meter test method, the OTDR can identify and locate any potential faults, macrobends or breaks that could impact network. VIAVI provides the widest range of OTDR testing tools delivering everything from basic fiber certification to fully automated bidirectional OTDR testing that scales for multi-fiber cable certification. This procedure. An Optical Time Domain Reflectometer (OTDR) is the most powerful tool for characterizing fiber optic networks. It works like "radar for fiber optics," sending light pulses down the fiber and analyzing the reflected light to measure loss, locate faults, and verify installations.

    [PDF Version]
  • How often is relay protection annual calibration required

    How often is relay protection annual calibration required

    110 (4), ER (Electricity Regulations) 1994; any protective relay and device of an installation will need to be checked, tested and calibrated by a competent person at least once every two years, or at any time as directed by the Energy Commission. Environment, load cycles, and operating conditions dictate recalibration frequency. Protection Relay Calibration required once in 2 years, by law – All electrical panels and switchboards have protection relays called earth fault and over-current relays which must trip the power supply in the event a. For reliable service of protective relaying excellent maintenance is a must. Setting determines pick-up value/time. Tests are conducted by the. Calibration and testing of protective relays require a systematic approach, incorporating both manual procedures and advanced automation techniques. Engineers in this field must familiarize themselves with detailed testing protocols, understand the implications of even slight deviations, and work. Protective circuit functional testing, including lockout relay testing, must take place immediately upon installation, every 2 years thereafter, and upon any change in wiring.

    [PDF Version]

Still Have a Technical Question?

Our team can help review your product selection.

Ask Our Team